Experience Best-in-Class Product Selection with
eCAPS®
search
search
Welcome expand_more
  • done Logout
Greenheck Greenheck
  • PRODUCTS

    Products

    Fans Fans
    arrow_back_ios Products Menu close

    Fans

    View All
    Air Circulators Axial Condenser Blowers & Utility Sets Ceiling & Bathroom Directional Destratification Fan Arrays Fume Exhaust Inline Jet Fans Laboratory Exhaust Overhead HVLS Plenums Roof Wall
    Dampers Dampers
    arrow_back_ios Products Menu close

    Dampers

    View All
    Combination Fire Smoke Smoke Fire Ceiling Radiation Control Bubble Tight & Isolation Balancing Backdraft Relief Industrial Doors Actuators
    Louvers Louvers
    arrow_back_ios Products Menu close

    Louvers

    View All
    Conventional Stationary Wind Driven Rain Hurricane Operable FEMA Acoustical Louvered Penthouse Equipment Screen Brick Vent
    Dedicated Outdoor Air Systems Dedicated Outdoor Air Systems
    arrow_back_ios Products Menu close

    Dedicated Outdoor Air Systems

    View All
    Dedicated Outdoor Air Systems (DOAS) - 100% Outside Air Dedicated Outdoor Air Systems (DOAS) with Energy Recovery Indoor Dedicated Outdoor Air Systems (DOAS) - 100% Outside Air
    Packaged Rooftop Units Packaged Rooftop Units
    arrow_back_ios Products Menu close

    Packaged Rooftop Units

    View All
    Packaged Rooftop Units Packaged Rooftop Units with Energy Recovery Dedicated Outdoor Air Systems (DOAS) - 100% Outside Air
    Energy Recovery Ventilators Energy Recovery Ventilators
    arrow_back_ios Products Menu close

    Energy Recovery Ventilators

    View All
    Energy Recovery Ventilators Energy Recovery Ventilators with Tempering Residential Energy Recovery Ventilators
    Make-up Air Units Make-up Air Units Gravity Ventilation Gravity Ventilation Kitchen Ventilation Kitchen Ventilation
    arrow_back_ios Products Menu close

    Kitchen Ventilation

    View All
    Exhaust Hoods Residential Range Hoods Hood Filtration External Supply Plenums Fire Suppression Pollution Control Utility Distribution Controls
    Duct Heaters Duct Heaters Air Measuring Products Air Measuring Products Accessories & Complimentary Products Accessories & Complimentary Products
    arrow_back_ios Products Menu close

    Accessories & Complimentary Products

    View All
    Controls Curbs & Mounting Motor Starters
  • Building Types

    Building Types

    Warehouses Warehouses Healthcare Facilities Healthcare Facilities Offices Offices Restaurants Restaurants K-12 School K-12 School
  • Resources

    Resources

    Drawings Drawings
    arrow_back_ios Resources Menu close

    Drawings

    View All
    Fans Energy Recovery Ventilators Dedicated Outdoor Air Systems Rooftop Units Make-Up Air Dampers Duct Heaters Louvers Gravity Ventilators Drawing Request
    Software Software
    arrow_back_ios Resources Menu close

    Software

    View All
    eCAPS® eCAPS Bridge for Revit® CAPS® Psychrometric Calculator
    Resource Library Resource Library
    arrow_back_ios Resources Menu close

    Resource Library

    View All
    Blog Post Case Study Catalog Installation Manual Podcast Specification Submittal Video White Paper
    Blog Blog Fan Energy Index Fan Energy Index FAQs FAQs
    arrow_back_ios Resources Menu close

    FAQs

    View All
    Product FAQs Parts FAQs Software FAQs
  • Education

    Education

    Online Trainings Online Trainings HVAC University HVAC University
  • Support

    Support

    Pre-Construction Pre-Construction Post-Construction Post-Construction
FIND MY REP
Greenheck Greenheck
Close
Main Menu
Products Menu
Products Menu
Products Menu
Products Menu
Products Menu
Products Menu
Products Menu
Products Menu
Main Menu
Main Menu
Resources Menu
Resources Menu
Resources Menu
Resources Menu
Main Menu
Main Menu
Products
Fans
View All
Dampers
View All
Louvers
View All
Dedicated Outdoor Air Systems
View All
Packaged Rooftop Units
View All
Energy Recovery Ventilators
View All
Kitchen Ventilation
View All
Accessories & Complimentary Products
View All
Building Types
Resources
Drawings
View All
Software
View All
Resource Library
View All
FAQs
View All
Education
Support
manage_accounts Log In clarify FIND MY REP
  1. Home
  2. arrow_forward_ios
  3. Resources
  4. arrow_forward_ios
  5. FAQs
  6. arrow_forward_ios
  7. Product FAQs
  8. arrow_forward_ios
  9. Make-Up Air FAQs

Product FAQs

  • Dampers FAQs
  • Louvers FAQs
  • Duct Heaters FAQs
  • Make-Up Air FAQs
  • Roof Mounted Fans FAQs
  • Ceiling Exhaust Fans FAQs
  • Energy Recovery Ventilators FAQs
  • Gravity Ventilators FAQs
  • Centrifugal Blowers FAQs
  • Inline Fans FAQs
Make-Up Air FAQs

 

Answers to your most Frequently Asked Questions about Greenheck make-up air units.

 

Q.
Q. Are equipment supports the same height as curbs?
A:
A: Not always. Combination curbs (FPEs) and evaporative cooling can cause these to change. Greenheck's CAPS selection program will provide the proper heights.
Q.
Q. Are face & bypass dampers available for steam and hot water coils in make-up air units?
A:
A: Yes. They can be selected in Greenheck's CAPS program with discharge air control.
Q.
Q. Can a direct fired unit be controlled by a building management system?
A:
A: Yes, the burner can be set up for an external 2-10vdc or 4-20ma signal to modulate the heat output. The fan and burner circuit can be energized through the BMS with dry contacts.
Q.
Q. Can evaporative cooling be added to an existing unit in the field?
A:
A: It may be possible to add evaporative cooling to an existing unit. If the airflow is in the low range for the housing size, the chances are good that evaporative cooling can be added in the field. Each case needs to be evaluated individually. Please consult the factory with this unit serial number.
Q.
Q. Can I get an indirect fired unit in a vertical configuration?
A:
A: No, the indirect fired unit is available in a horizontal or down blast configuration only.
Q.
Q. Can make-up air units that have direct gas heat be mounted indoors?
A:
A: Yes. Structural support requirements are by others. Note - indoor mounting of units with evaporative cooling is not recommended.
Q.
Q. Can make-up air units that have indirect gas heat be mounted indoors?
A:
A: Yes. Indoor installation is selectable in CAPS®. With that selection you will need to specify the type of combustion gas venting required. See page 16 of Greenheck’s Indirect Gas-Fired Technical Guide for specifics. However, structural support requirements are from others outside of Greenheck. Note - all Greenheck indirect gas units are power vented. Indoor mounting of units with evaporative cooling is not recommended.
Q.
Q. Can you add a variable frequency drive (VFD) to the make-up air units? Which units?
A:
A: All make-up air units can have a VFD added. The direct fired units require a burner by-pass damper to keep the air velocity constant across the burner at all times. This option is selectable in 3.10 CAPS. Airflow turndown can be down to 50% and greater on some units depending on the start point on the fan curve. The CAPS program will tell you how much you can reduce air flow when making the unit selection.
Q.
Q. How does freeze protection work?
A:
A: Freeze protection consists of an on/off duct stat and timer that prevents the discharge of cold air into the building when the burner is not providing adequate tempering. If the discharge temperature is below the set point, the make-up air unit is shut off.
Q.
Q. Is freeze protection available for steam and hot water coils?
A:
A: Yes. However, it is very different from freeze protection for a gas heat unit. If the coil face temperature drops below the set point, the blower will shut down until the coil temperature rises.
Q.
Q. Is it possible to supply a remote control panel for an existing unit in the field?
A:
A: Yes. Please consult the factory with the unit serial number and the requested remote control panel options.
Q.
Q. What does an inlet air sensor do?
A:
A: An inlet air sensor consists of an on/off duct stat that automatically de-energizes the burner when outside air temperature is near or equal to the desired discharge air temperature. Typically, this option is used to prevent the burner from firing on mild days.
Q.
Q. What does ETL stand for?
A:
A: Intertek Listed, formally known as Edison Testing Laboratories (ETL). The ETL mark is an alternative to American Gas Association (AGA). ETL is a listed mark and is accepted and recognized by jurisdictions across the US and Canada. ETL is nationally recognized by the major building code agencies: Building Officials and Code Administrators International (BOCA-ES), International Conference of Building Officials (ICBO-ES), and Southern Building Code Congress International Inc. (SBCCI PST & ESI). These agencies establish building codes and standards which most municipalities and states adopt as their own. The ETL label is provided on direct fired units where Greenheck supplies the control center.
Q.
Q. What is included in a control center and where is it located?
A:
A: Control centers include a factory pre-wired disconnect switch, terminal blocks, transformers, fuses, overloads, and starters. A Greenheck control center provides the benefit of a single point wiring connection in the field. Greenheck requires a control center for all gas-fired make-up air units.
Q.
Q. What is the difference between Maxitrol 14 and Maxitrol 44 direct gas-fired controls?
A:
A: Maxitrol 14 uses a discharge air sensor and a discharge temperature selector to control air temperature at the point of discharge for direct gas-fired units only. A room override thermostat is available for the Maxitrol 14, which boosts the discharge temperature when the room temperature is below set point. Maxitrol 14 is commonly found in kitchens, restaurants, paint spray booths and other industrial applications. A Maxitrol 44 controls space temperature with a remote mounted thermostat for direct gas-fired units only. This control creates an even air temperature for the total space similar to heating a room in a home. Common applications include factories and warehouses.
Q.
Q. What is the recommended minimum service clearance for make-up air units?
A:
A: The recommended minimum for housing 32 and less is 42 inches on the control's side of the unit. On housing 35 and larger the recommended minimum is 48 inches on the controls side of the unit. Note - clearances for component removal may be greater than the service clearances listed.
Q.
Q. What is turndown ratio and is it different for direct vs. indirect gas heaters?
A:
A: Turndown ratio compares the maximum to minimum heat output. Turndown ratio for direct gas burners is 25:1, which means that the burner can modulate from 4% to 100% of full fire. Indirect gas turndown ratio changes based on the controls. Example based on a single furnace unit (< 400 MBH): 4:1 electric modulation limits the heat output from 25% to 100% of full fire. 8:1 stage limits the heat output from 12.5% to 100% of full fire. See the Indirect Gas-Fired Technical Guide for more information.
Q.
Q. What side of the unit are the controls located on? Can this be changed?
A:
A: When you are looking into the intake of the unit with the air hitting you in the back of the head, the controls and connections will be on the right side of the unit. Yes this can be changed, but requires a special design request (SDR). If you need the controls and connections on the opposite side, consult the factory.
Q.
Q. Where is direct gas fired heat not permitted?
A:
A: According to National Fire Protection Association (NFPA) 54, direct gas fired heat cannot be used in sleeping quarter areas. Please be aware that local authorities may have different interpretations or further restrictions. If you are not sure, please contact your local authorities for interpretation.

Products

    Fans Dampers Louvers Dedicated Outdoor Air Systems Packaged Rooftop Units Energy Recovery Ventilators Make-up Air Units Gravity Ventilation Kitchen Ventilation Duct Heaters Air Measuring Products Accessories & Complimentary Products

Building Types

  • Warehouses
  • Healthcare Facilities
  • Offices
  • Restaurants
  • K-12 School

Resources

  • Drawings
  • Software
  • Resource Library
  • Blog
  • Fan Energy Index
  • FAQs

Education

  • Online Trainings
  • HVAC University

Support

  • Pre-Construction
  • Post-Construction

About Us

  • Overview
  • News
  • Philosophy
  • Facilities
  • Global Manufacturing
  • Careers
  • Privacy Statement
  • Contact Us
Greenheck
©2026 Greenheck Fan Corporation. All rights reserved.
P.O. Box 410 Schofield, WI 54476 (715) 359-6171 Contact Us
CAREERS