Our office will be closed Monday, May 25th, in observance of Memorial Day. Orders will resume shipping Tuesday, May 26th.
| Shipping Type | Order By |
|---|---|
|
Standard Ground Small Parcel FREE - On orders over $25 View Transit Map |
7:00 PM CST |
|
Next Day Air (Calculated at checkout) |
3:00 PM CST |
|
Standard Ground Freight FREE - On orders over $25 |
1:00 PM CST |
| Shipping Type | Order By |
|---|---|
|
Standard Ground Small Parcel FREE - On orders over $25 View Transit Map |
7:00 PM CST |
|
Next Day Air (Calculated at checkout) |
3:00 PM CST |
|
Standard Ground Freight FREE - On orders over $25 |
1:00 PM CST |
| SKU | DESCRIPTION | PRICE | LEAD TIME | |||
|---|---|---|---|---|---|---|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure, Remote Transducer, Product # 872990 | $2,826.95 |
8 Days
Lead Time |
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Airflow Control, Remote Transducer with Pitot Tube, Product # 872989 | $2,107.41 |
8 Days
Lead Time |
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Remote Transducer with 2 Room Probes, Product # 872988 | $1,554.84 |
8 Days
Lead Time |
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Remote Transducer with Room Probe, Product # 872987 | $2,126.40 |
In stock
15 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Remote Transducer with Duct Probe, Product # 872986 | $2,173.49 |
In stock
2 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Airflow Control, Integral Transducer with Pitot Tube, Product # 872985 | $2,059.46 |
In stock
4 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Integral Transducer with 2 Room Probes, Product # 872984 | $1,571.81 |
In stock
2 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Integral Transducer with Room Probe, Product # 872983 | $1,521.86 |
In stock
5 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Integral Transducer with Duct Probe, Product # 872982 | $1,789.75 |
In stock
11 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
2-Speed Control, for use with Vari-Green motors, Product # 867010 | $567.92 |
In stock
3 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Transformer Retrofit Kit, Product # 867009 | $539.86 |
In stock
21 on Hand
|
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Remote Dial Speed Control, for use with Vari-Green motors, Product # 867008 | $553.89 |
In stock
15 on Hand
|
Add to Compare List |
|
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Power Wire Harness, 36 Inch, Product # 865314 | $40.68 |
8 Days
Lead Time |
Add to Compare List |
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Power Wire Harness, 18 Inch, Product # 865313 | $29.46 |
In stock
25 on Hand
|
Add to Compare List |
|
|
|
Model:
Model
Model / Size:
Selection Model
|
Vari-Green Constant Pressure Control, Integral Transducer with 2 Room Probes, Product # 863714 | - |
Obsolete
|
The Constant Airflow Control is used to monitor velocity pressure in a system, automatically adjusting the fan speed to maintain a desired velocity pressure (constant CFM). This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Airflow Control is used to monitor velocity pressure in a system, automatically adjusting the fan speed to maintain a desired velocity pressure (constant CFM). This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Constant Pressure Control can be used to monitor static pressure in a system, automatically adjusting the fan speed to maintain a desired static pressure. This control reduces energy consumption not only by reducing the speed and the energy used by the fan, but will also reduce the amount of conditioned air that is exhausted. Recommended for use in multi-family structures, hotels and schools where demand control ventilation applications exist.
The Vari-Green transformer provides a 24-volt power source from the existing line voltage at the fan to the motor and controls. It has two dry auxiliary contacts (one normally open and one normally closed) available to signal a motorized damper or interlock with other devices.