Number of Results: 82
Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-TH-500 is the simplest and most widely used variable air volume (VAV) terminal unit. Its primary function regulates airflow to an occupied space. Capacities ranging from 80-7,270 cfm in 10 sizes. Pneumatic, electric, analog, or direct digital controls available. Hot water or electric heat
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The VCD-43 control damper is low leakage with extruded aluminum airfoil blades and frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8
The VCD-33 is a low leakage control damper with fabricated airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in. wg Velocit
The VCD-23 is a general purpose control damper with 3V blades. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Velocity: Up to 3
The VCD-42 is a low leakage control damper with extruded aluminum airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 6 in. wg Leakage: 3 cfm per sq. foot @ 1in. wg, 6 cfm per s
Model VCD-40 is a low leakage control damper that has blades completely contained within the 4 in. frame. This allows the direct mount to a louver, filter frame, or similar application with no blade interference. Pressure: Up to 6 in. wg Leakage: Class 1A @ 1 in. wg Velocity: Up to 6000 fpm Tempera
The VCD-34 is a low leakage control damper that has insulated fabricated airfoil blades. The damper works well in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in
The VCD-20 is a general purpose control damper with 3V blades. This damper can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Velocity: Up to 3000 fpm Temperature: -40°F to 250°F
Model XG-2300CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/4-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2000CO is an extruded aluminum core only linear bar grille with 7/32-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2500CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-6600MC-90 series is an extruded aluminum supply or return linear slot diffuser 90° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-6600MC-45 series is an extruded aluminum supply or return linear slot diffuser 45° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-6600MC-135 is an extruded aluminum supply or return linear slot diffuser 135° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-2000 is an extruded aluminum linear bar grille with 7/32-inch bars on 1/2-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2300 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/4-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2500 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/2-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2600 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/2-inch centers and 1/2-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2100 is an extruded aluminum linear bar grille with 7/32-inch bars on 1/2-inch centers and 1/2-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2400 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/4-inch centers and 1/2-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2200 is an extruded aluminum linear bar grille with 7/32-inch bars on 1/2-inch centers and 3/16-inch non flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2700H is an extruded aluminum linear bar grille with 1/8-inch bars on 1/2-inch centers and 3/16-inch non flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2800H is an extruded aluminum linear bar grille with 1/8-inch bars on 1/4-inch centers and 3/16-inch non flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-6600 series is an extruded aluminum supply or return linear slot diffuser, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-AFLI is an extruded aluminum architectural square (Integra) linear slot diffuser, available in one-inch to 2 two-inch slot widths and one or two slots.
Model XG-AFLIH is an extruded aluminum architectural square high-capacity return (Integra) linear slot diffuser, available in one-inch to 2 two-inch slot widths and one or two slots.
Model XG-AFL-MC is an extruded aluminum architectural linear slot diffuser mitered corner section, available in 90°, 135°, or special angles, one-inch to three-inch slot widths and one or two slots.
Model XG-AFL-MCC is an extruded aluminum architectural linear slot diffuser mitered corner section with concealed mounting hardware, available in 90°, 135°, or special angles, one-inch to three-inch slot widths and one or two slots.
Model XG-FCI-600 is a fan-powered terminal unit engineered to provide a balance between quiet operation, minimal footprint, and a broad flow range. All XG-FCI-600 terminal units are AHRI certified and shipped with the AHRI seal. Capacities ranging from 200-4,400 cfm in six casing sizes. Pneumatic,
Model XG-FCL-600 low profile fan-powered terminal units provide a balance between quiet operation, minimal footprint, and a broad flow range with a reduced height for low clearance ceiling applications. Every XG-FCL-600 includes a bottom rigid access panel. These simple-to-remove panels provide acc
Model XG-FCQ-700 quiet fan-powered air terminal units provide noise levels that are the best in the business. The XG-FCQ-700 includes industry-leading tuned inlet and discharge attenuators and each unit is AHRI certified and shipped with the AHRI seal. Capacities ranging from 200-4,400 cfm in six c
Model XG-2100MC is an extruded aluminum linear bar grille mitered corner section with 7/32-inch bars on 1/2-inch centers and 1/2-inch flanged frame, available in 90°, 135° or special angles (SA) with 0°, 15°, or 30° blade deflection.
Model XG-TL-500 single duct air terminal unit is for low-profile applications. The unit is served by a central air handler and modulates the amount of primary cooling air to the space between a minimum set point and the design airflow. Its construction uses industry-leading continuous welded primar
Model XG-BP-600 is a bypass air terminal unit used to achieve variable air volume delivery of of conditioned air to a space or zone where constant volume air handlers exist. The XG-BP-600 delivers a constant volume of air, but varying amounts are delivered to the space and the bypass plenum. Capaci
Model XG-FVI-500 variable volume parallel fan-powered air terminal units provide superior comfort to zones by intermittent parallel fan operation and offer lower operating costs. Capacities ranging from 150-5,600 cfm in seven casing sizes. Pneumatic, electric, analog, or direct digital controls ava
Model XG-FVL-600 parallel fan-powered terminal unit is designed to provide superior comfort to zones by intermittent parallel fan operation. These air terminal units have reduced height for low clearance applications, are AHRI Certified and ETL listed. Capacities ranging from 200-2,500 cfm in three
Model XG-DD-500 air terminal units regulate the flow of conditioned air in a dual duct air distribution system. The air terminal unit receives both heated and cooled air and mixed in a plenum (provided by others) to reach the desired discharge temperature. The XG-DD-500 offers a CFM range capacity
Model XG-DH-500 is a high-performance air terminal unit designed to regulate the flow of conditioned air in dual duct air distribution systems. Both heated and cooled air are provided to the air terminal and mixed in an integral plenum to reach the desired discharge temperature. The XG-DH-500 provi
Model XG-DS-600 short mixing dual duct air terminals regulate the flow of conditioned air and or outside air in air distribution systems. The XG-DS-600 takes heated and cooled conditioned air, heated or cooled conditioned air along with outside air to the air terminal and mixes the air in an integra
Model XG-6675TZ4 (supply) is a four-inch wide extruded aluminum linear slot diffuser with 3/4-inch slot width compatible with TechZone™ style ceiling systems.
Model XG-SR-500 products fit into existing low pressure square or rectangular duct systems. The XG-SR-500 offers multiquadrant, averaging flow sensor for highly accurate (+/-5%) readings with varying inlet duct configurations after a certified balancer balances the terminal. Capacities ranging from