Number of Results: 434
Model XG-RHE is a premier extruded aluminum return and exhaust grille, offering superior construction for high performance and durability. The XG-RHE is available in a number of borders to integrate into a wide range of ceiling and sidewall applications.
Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-TH-500 is the simplest and most widely used variable air volume (VAV) terminal unit. Its primary function regulates airflow to an occupied space. Capacities ranging from 80-7,270 cfm in 10 sizes. Pneumatic, electric, analog, or direct digital controls available. Hot water or electric heat
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-CC1 is an aluminum sidewall or ceiling return/exhaust grille with one-inch x one-inch x one-inch cube core designed to provide low pressure drops and low sound levels. Available in 3-week Industry-leading lead times.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model HLC-FFR radial discharge pattern diffusers are engineered for supply air distribution in critical environments such as chemistry labs and clean rooms. The diffusers are engineered to supply a low velocity of conditioned air in a radial pattern from the ceiling. Product Features: Low velocity
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
VAB belt drive models offer flexibility to adjust pulleys and easy access to the motor with low vibration level for smooth operation. System balancing is made through sheave changes or manually adjustable blade pitch. 2,000 to 145,000 cfm Up to 7.5 in. wg
Model XG-MRDD is an aluminum round architectural double deflection grille with individually adjustable deflection blades.
Model XG-MRDDW is an aluminum round architectural double deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MREC is an aluminum round architectural egg crate grille.
Model XG-MRPF is an aluminum round architectural perforated grille.
Model XG-MRSD is an aluminum round architectural single deflection grille with individually adjustable deflection blades.
Model XG-MRSDW is an aluminum round architectural single deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MPK is an aluminum punkah louver that discharges a directable high-velocity jet to condition a specific space or area.The XG-MPK is constructed using a felt gasket that allows smooth movement of the inner core to direct air flow and provide a tight seal to prevent air leakage.
Model XG-JA diffusers are an excellent choice for high-capacity, long throw applications. The modular design of the XG-JA allows selection for a wide range of air volumes.
Model XG-EPRH is a plastic 2 foot x 2 foot lay-in louver face return grille.
Model XG-EPRHF is a plastic 2 foot x 2 foot lay-in louver face filter return grille with 1 inch deep filter rack.
The WDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. Galvanized steel frame Aluminum blade Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperatu
The SSWDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. 304 stainless steel construction Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperature:
The GM-30 series backdraft dampers allow horizontal airflow and prevent reverse airflow. Dampers in this series include the GM-30 (no flange), GM-31 with a flange on discharge and GM-32 with a flange on intake. Air pressure differential with assistance from adjustable counterbalance weights to mini
Model EMV-11 horizontal mount, backdraft damper allows vertical airflow up and prevents reverse airflow down. The damper is opened by air pressure differential and closed by gravity. Standard models include adjustable counterbalance weights to assist with opening. Aluminum construction Pressure: Up
The EM-10 series are horizontally mounted backdraft dampers designed to allow vertical airflow up and prevent reverse airflow down. Model EM-10 has no flange, model EM-11 has a flange on the discharge side, and model EM-12 has a flange on the intake side. All dampers in this series open by air pres
The EM-40 series are horizontally mounted backdraft dampers designed to allow vertical airflow down and prevent reverse airflow up. Model EM-40 has no flange, model EM-41 has a flange on the discharge side, and model EM-42 has a flange on the intake side. All dampers in this series open by air pres
The EM-30 series are vertically mounted backdraft dampers designed to allow horizontal airflow. Model EM-30 has no flange, model EM-31 has a flange on the discharge side, and model EM-32 has a flange on the intake side. All dampers in this series open by air pressure differential and close by gravi
The BD-300 series backdraft dampers mount vertically to allow horizontal airflow and prevent reverse airflow. Dampers in this series: BD-300 with a flange on intake, BD-320 with a flange on discharge and BD-330, which does not have a flanged frame. All dampers in this series open by air pressure di
The BD-90 backdraft damper mounts horizontally to allow vertical airflow up and prevent reverse airflow down. The dampers are open by air pressure differential and closed by gravity. Pressure: Up to 2 in. wg Velocity: Up to 1500 fpm Temperature: Up to 180°F Accessory to power roof ventilators and c
The BD-100 backdraft damper mounts horizontally to allow vertical airflow up and prevent reverse airflow down. The dampers are open by air pressure differential and closed by gravity. Pressure: Up to 2 in. wg Velocity: Up to 1500 fpm Temperature: Up to 180°F Accessory to power roof ventilators and
Model AFJ-801 acoustical louver protects air intake and exhaust openings in exterior walls. The insulated J-style blades provide high free area and low airflow resistance while also reducing airborne noise transmission. 8-inch depth 27% free area (4 ft. x 4 ft.) 887 fpm free area velocity at the be
AFJ-120 acoustical louvers protect air intake and exhaust openings in exterior walls. The insulated J-style blades provide high free area and low airflow resistance while reducing airborne noise transmission. Model AFJ-120 provides the best sound transmission class rating in its class. 12-inch dept
Model AFJ-601 acoustical louver protects air intake and exhaust openings in exterior walls. The insulated J-style blades provide high free area and low airflow resistance while also reducing airborne noise transmission. Model AFJ-601 offers the best balance of free area and sound transmission in it
Manufactured of heavy-gauge aluminum, model ESJ-155 is commonly used for interior or exterior applications where high free area and low airflow resistance is required along with a narrow frame profile. 1 ½-inch depth 46% free area
Model AFL-501 is a severe-duty aluminum tornado louver designed to protect air intake and exhaust ventilation openings on FEMA 361/320 storm shelters or safe rooms. It is tested in accordance with the stringent ICC 500-20 test standard and is UL Listed. Model AFL-501 is available in several install
Model AFL-601 is an all-in-one wind-driven rain FEMA dual-module with horizontal front blades and vertical rear blades designed to protect air intake and exhaust ventilation openings on FEMA 361/320 storm shelters or safe rooms. It is tested in accordance with the stringent ICC 500 (2020 & 2023) te
Model EES-401 is an extruded aluminum equipment screen with inverted horizontal J-blade louvered equipment screen. Design characteristics lend itself for multiple configuration options. These options include multi-sided configurations that may be provided with mitered or formed box style corners as
Model AFA-801 acoustical louver protects air intake and exhaust openings in exterior walls. The insulated airfoil-style blades provide high free area and low airflow resistance while reducing airborne noise transmission. Model AFA-801 provides the highest free area in its class. 8-inch depth 33% fr
Manufactured of heavy-gauge aluminum, model ESU-154 is commonly used for interior or exterior applications where high free area and low airflow resistance is required. Its narrow depth is ideal for PTAC and curtainwall window applications. 1 ½-inch depth 53% free area
Manufactured of heavy-gauge aluminum, model ESU-153 is commonly used for interior or exterior applications where high free area and low airflow resistance is required. Its narrow depth is ideal for PTAC and curtainwall window applications. 1 ½-inch depth 70% free area
The WD-400 backdraft damper series are non-motorized that mount vertically for intake air or horizontally to allow vertical airflow down and prevent reverse airflow. Models WD-400 and 410 have no flange, model WD-420 has a flange on discharge, and WD-430 has a flange on intake. The dampers open usi
The WD-340 backdraft damper bolts to the flanged outlet of Greenheck model USF utility blowers. Motorpacks are optional. Pressure: Up to 2 in. wg Velocity: Up to 2500 fpm Temperature: Up to 180°F
The WD-300 series backdraft damper prevents reverse airflow in horizontal exhaust applications. Model WD-300 has a flange on intake, model WD-320 has a flange on discharge and model WD-330 does not have a flanged frame. Dampers open using air pressure differential and close by gravity. Optional mot
The WD-200 series backdraft dampers are motorized to open when energized and the spring return closes when de-energized. Model WD-200 has no flange, model WD-210 has a flange on the motor side and model WD-220 has a flange opposite the motor. The WD-200 series is for horizontal or vertical mounting
The WD-100 series backdraft dampers mount horizontally to allow vertical airflow up and prevent reverse airflow. Model WD-100 has no flange, model WD-110 has a flange on the discharge side, and model WD-120 has a flange on the intake side. These dampers open using air pressure differential (assiste
VAD direct drive model has the most compact design for the available performance range with minimal maintenance and low vibration levels. Final system balancing uses manually adjustable blade pitch. 1,200 to 240,000 cfm Up to 10 in. wg
BVF Brick Vents make possible simplified installation in existing walls. The brick vents are designed with an overlapping louver blade. They incorporate a 7 x 7 mesh insect screen and a high waterstop at the rear of the brick vent.
BVE Brick Vents are the answer where a fine finish is a prerequisite, where a superior brick vent is required at a minimum cost. The brick vents are designed with a deep louvered overlapping blade and incorporate a 7 x 7 mesh insect screen.