Number of Results: 51
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The SEFSD-211 is a severe environment 316SS combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 316 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up
The SSFSD-211 is a 304 stainless steel combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 304 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 35
The SSSMD-201 is a Class I leakage rated smoke damper with 304 stainless steel construction and 3V blades. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
Model EHV-901 is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-901 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
Model EHV-901D is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-901 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EHV-550 is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-550 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
Model EHV-550D is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust opening in exterior walls. EHV-550D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EHH-601D is a Miami-Dade Qualified and Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-601D is AMCA 540 Listed for wind-borne debris impact and is a high-performance AMCA
Model EHH-601DE is a Miami-Dade Qualified and Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-601DE is AMCA 540 Listed for wind-borne debris impact and is a high performing AMCA
Model EHH-501X is a Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-501X is AMCA 540 Listed for wind-borne debris impact when selected as such and is a high-performance AMCA 500
Model EHH-201 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head and horizontal rain resistant blades to provide exceptional resistance to wind driven rain. 2-inch depth 39% free area (4 ft. x 4 ft.) 973 fpm free area velo
Model EHH-601 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head. Horizontal rain resistant blades provide exceptional resistance to wind driven rain. 6-inch depth 47% free area (4 ft. x 4 ft.) 1,250 fpm free area velocity
Model EHH-701 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head. Horizontal rain resistant blades provide exceptional resistance to wind driven rain. 7-inch depth 44% free area (4 ft. x 4 ft.) 1,250 fpm free area velocity
Model EHH-401 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head. Horizontal rain resistant blades provide exceptional resistance to wind driven rain. 4-inch depth 42% free area (4 ft. x 4 ft.) 1,043 fpm free area velocity
Model EHH-501 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head. Horizontal rain resistant blades provide exceptional resistance to wind driven rain. 5-inch depth 43% free area (4 ft. x 4 ft.) 1,250 fpm free area velocity
Model EVH-501D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-501D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EVH-501 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head and vertical rain resistant blades to provide exceptional resistance to wind driven rain. 5-inch depth 54% free area (4 ft. x 4 ft.) 1,250 fpm free area velo
Model EVH-660D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-660D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EVH-302 protects air intake and exhaust openings in exterior walls sensitive to water penetration. The design features a drainable head and vertical rain resistant blades to provide exceptional resistance to wind driven rain. 3-inch depth 51% free area (4 ft. x 4 ft.) 1250 fpm free area veloc
Model EVH-302D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-302D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
The FSD-331 is a combination fire smoke damper with airfoil blades. This model is rated for use in walls, floors, or partitions with a fire resistance rating of 3 hours or more and a Class I leakage rating. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
Model FSD-212 is a combination fire smoke damper with 3V blades. It installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watch N
The FSD-312 is a combination fire smoke damper with airfoil blades. It is rated for airflow and leakage in either direction and installs in walls, floors, or partitions. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watc
The FSD-311V is a vertical blade combination fire smoke damper with airfoil style blades. This model installs in walls or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4,000 fpm Temperature: Up to 250°F 10-Day Fixed Lead Times on Selec
The FSD-211 is a combination fire smoke damper with 3V-style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2,000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurat
The FSD-311M is a modulating combination fire smoke damper with airfoil style blades. It is rated for airflow and leakage in either direction and installs in walls, floors, or partitions. Pressure: Up to 4 in. wg Velocity: Up to 2,000 fpm Temperature: Up to 250°F 10-Day Fixed Lead Times on Select C
The FSD-311 is a combination fire smoke damper with airfoil blades. This model installs in walls, floors, or partitions and has a rating for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configur
The FSD-213 is a combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and has a rating for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configuration
The FSD-211M is a modulating combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 250°F 10-Day Fixed Lead Times on Select Confi
The SMD-201M is a Class I rated modulating smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperatur
The SMD-201 is a Class I leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: U
The SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature:
The SMD-302M is a Class II leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Tempera
The SMD-302 Class II leakage rated smoke damper has airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301V is a Class I leakage rated smoke damper with vertical airfoil blades for operational closure in emergency smoke control situations. This model installs vertically and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301M is a Class I leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 f
The SMD-401M is a Class I leakage rated modulating smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velo
The SMD-401 is a Class I leakage rated smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to
The SMD-301 is a Class I leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperatur
The RBS is a belt drive axial fan, ideal for roof-mounted supply applications. Units feature fabricated steel propellers and a fabra hood-style aluminum or steel housing. 500 to 86,500 cfm Up to 1.5 in. wg.
This is a belt drive, roof-mounted axial fan specifically for filtered supply applications. The RBF features fabricated steel propellers and a fabra hood-style housing constructed of steel or aluminum. 1,700 to 79,600 cfm Up to 1.5 in. wg.
The RBE belt-driven axial fan is ideal for roof-mounted applications exhausting relatively clean air. These units feature fabricated steel propellers and a fabra hood-style housing. 1,340 to 82,283 cfm Up to 1.5 in. wg.
An RBCE belt drive, roof mounted axial fan is for applications exhausting relatively clean air. Fan propellers are cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 830 to 78,000 cfm Up to 1. 0 in. wg.
The RE2 has fabricated steel propellers with a fabra hood-style aluminum or steel housing. The unit is a direct drive, roof mount axial fan for applications exhausting relatively clean air. 1,200 to 41,470 cfm Up to 2.0 in. wg.
Model RCE3 is a direct drive, roof mount axial fan designed for applications exhausting relatively clean air. Fan propellers are cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 580 to 42,290 cfm Up to 1.5 in. wg.
Model RCS3 is a direct drive, axial fan designed for roof mount, supply applications. Fan propellers are cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 600 to 46,870 cfm Up to 1.25 in. wg.
Model RSF is a belt drive, roof-mounted supply fan. It provides unrestricted airflow and maximum weather protection. Each unit features a forward-curved wheel and heavy gauge galvanized steel housing. 600 to 16,300 cfm Up to 2.0 in. wg.
Model RS2 is a direct drive, axial fan designed for roof-mount, supply applications. Fan propellers are fabricated steel with fabra hood-style aluminum or steel housings. 1,700 to 44,220 cfm Up to 1.5 in. wg.
The RBCS is a belt drive, axial fan for roof-mount supply applications. Fan propellers are constructed of cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 1,025 to 79,700 cfm Up to 1. 0 in. wg.