Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The intended use for FBV-23 face and bypass control dampers are in low to medium pressure and velocity systems. The control damper features 3V blades and is IECC (International Energy Conservation Code) compliant. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1 in. wg; Class 1 @ up to 5 in. wg Veloc
The VCDRM-53 is an insert type multi-blade round control damper providing airflow control in round HVAC ductwork. This damper has applications in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: 3½ cfm per sq. foot @ 1 in. wg Velocity: Up to 2500 fpm Temperature: Up to
Model ICD-45 is low leakage control damper with aluminum extruded blades and frame that are insulated and thermally broken. The model minimizes the transfer of thermal energy and reduces condensation. It meets the requirements of IECC (International Energy Conservation Code). Pressure: Up to 8 in.
The ICD-44 is a low leakage control damper with aluminum extruded blades that are thermally broken. The control damper minimizes transfer of thermal energy and reduces condensation. It meets the requirements of IECC (International Energy Conservation Code). Pressure: Up to 8 in. wg Leakage: Class 1
Model EHV-901 is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-901 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
Model EHV-901D is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-901 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EHV-550 is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-550 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
Model EHV-550D is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust opening in exterior walls. EHV-550D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EHH-601DE is a Miami-Dade Qualified and Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-601DE is AMCA 540 Listed for wind-borne debris impact and is a high performing AMCA
Model EHH-601D is a Miami-Dade Qualified and Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-601D is AMCA 540 Listed for wind-borne debris impact and is a high-performance AMCA
Model EHH-501X is a Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-501X is AMCA 540 Listed for wind-borne debris impact when selected as such and is a high-performance AMCA 500
Model EVH-501D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-501D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EVH-660D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-660D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
Model EACA-601D is a Miami-Dade Qualified and Florida Product Approved combination louver-damper that protects air intake and exhaust openings in exterior walls. The design allows the damper blades to be open or closed and is most often supplied with factory mounted and adjusted electric actuators.
Model EVH-302D is a Miami-Dade Qualified and Florida Product Approved stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EVH-302D is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Veloc
The VCDR-53 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Leakage: 4 cfm per sq. foot @ 1 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F Blade seal
The VCDR-50 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The VCD-43 control damper is low leakage with extruded aluminum airfoil blades and frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8
The VCD-33 is a low leakage control damper with fabricated airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in. wg Velocit
The VCD-23 is a general purpose control damper with 3V blades. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Velocity: Up to 3
The VCD-42 is a low leakage control damper with extruded aluminum airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 6 in. wg Leakage: 3 cfm per sq. foot @ 1in. wg, 6 cfm per s
Model VCD-40 is a low leakage control damper that has blades completely contained within the 4 in. frame. This allows the direct mount to a louver, filter frame, or similar application with no blade interference. Pressure: Up to 6 in. wg Leakage: Class 1A @ 1 in. wg Velocity: Up to 6000 fpm Tempera
The VCD-34 is a low leakage control damper that has insulated fabricated airfoil blades. The damper works well in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in
The VCD-20 is a general purpose control damper with 3V blades. This damper can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Velocity: Up to 3000 fpm Temperature: -40°F to 250°F
The VCD-23V control damper has vertical 3V blades with blade and jam seal. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Veloc
The VCD-33V is a low leakage control damper with vertical fabricated airfoil blades. The model can be used as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up 4-8 in. wg Velocity: Up
The VCD-34V is a low leakage control damper with insulated vertical fabricated airfoil blades. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @
The VCD-43V control damper has low leakage with extruded aluminum airfoil blades and an aluminum frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg,
Model ESD-635DE is a Miami-Dade Qualified and Florida Product Approved stationary horizontal drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. ESD-635DE is AMCA 540 Listed for wind-borne debris impact and is approved for use in Florida’s
Model ESD-635X is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. The ESD-635X is AMCA 540 Listed for Wind-Borne Debris when selected as such and is approved for use in Florida’s High Velocity Hurr
Model ESD-435X is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. Model ESD-435X is AMCA 540 Listed for Wind-Borne Debris when selected as such and is approved for use in Florida’s High Velocity Hu
Model ESD-635D is a Miami-Dade Qualified and Florida Product Approved stationary horizontal drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. ESD-635D is AMCA 540 Listed for wind-borne debris impact and is approved for use in Florida’s H
Model XG-2000CO is an extruded aluminum core only linear bar grille with 7/32-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2300CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/4-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2500CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-6600MC-45 series is an extruded aluminum supply or return linear slot diffuser 45° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-6600MC-90 series is an extruded aluminum supply or return linear slot diffuser 90° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-6600MC-135 is an extruded aluminum supply or return linear slot diffuser 135° mitered corner section, available in 1/2-inch to 1-1/2-inch slot widths and one to eight slots. Available in 3-week Industry-leading lead times.
Model XG-2000 is an extruded aluminum linear bar grille with 7/32-inch bars on 1/2-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2300 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/4-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2500 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/2-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.