Number of Results: 79
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
The SSSMDR-501 is a Class I leakage-rated round smoke damper constructed of 304 stainless steel. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
The CFSD-211 is a combination fire smoke damper for corridor ceiling applications and has UL 555 1 hour fire rating and UL 555S leakage class I. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watch Now to Learn More!
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
Model GFSD-211 is an out of wall combination fire smoke damper with 3V blades. Its design allows for easy access through the grille to the damper, closure device, and the actuator. This model can install vertically or horizontally and is rated for airflow and leakage in either direction. UL 555 1½
Model OFSD-311 is an out-of-wall combination fire smoke damper with airfoil blades. It is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure
Model OFSD-211 is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This combination fire smoke damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Tempera
Model OFSD-212 is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
The SEFSD-211 is a severe environment 316SS combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 316 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
The SSFSD-211 is a 304 stainless steel combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 304 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 35
The SSSMD-201 is a Class I leakage rated smoke damper with 304 stainless steel construction and 3V blades. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The SSFSDR-511 has round blades. This model installs in walls, floors, and partitions and is rated for airflow and leakage in either direction. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: 350°F
Model ABD is an automatic balancing damper designed to maintain a constant airflow volume in HVAC applications. The damper blade is calibrated to automatically adjust to changing pressures. The ABD is for use in both supply and exhaust applications. Pressure: 0.2 in. wg to 2 in. wg Airflow Range: 25
Model ABD-FD is an automatic balancing damper with a UL 555 rated 1½ or 3 hour static fire damper. The entire assembly is UL rated and approved. The ABD is designed to maintain a constant airflow volume in a HVAC application and calibrated to automatically adjust to changing pressures. The assembly
The ABD-Z1 provides on-demand control to a ventilation system. The ABD-Z1 has a shut off damper with an electric actuator, automatic balancing damper (ABD), and a plenum box as one assembly. It is designed to maintain a constant airflow volume in a HVAC applications. Building Types Apartments and Co
Model ABD-T is an automatic balancing damper with a square transition. This damper is designed to maintain a constant airflow volume in HVAC applications. The damper blade is calibrated to automatically adjust to changing pressures. The transition can be removed and flipped to the other side of the
Model ABD-RB combines an automatic balancing damper (ABD) with the convenience of a factory-supplied register box. The ABD-RB can be configured for supply or exhaust applications and can mount in walls and ceilings. The ABD can mount on either the side or back of the register box. Applications Apart
The ABD-Z2 has an integrated automatic balancing damper (ABD) that can be toggled between two pressure independent cfm setpoints by way of an electric actuator. The low-flow setpoints maintains a constant mimum ventilation rate, while the high-flow setpoint provides boosted on-demand ventilation. Bu
The CRD-1 is an ETL Listed damper designed to limit radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-1LP is a UL 555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less. This model is intended for use on applications with limited blade clearance.
The CRD-1 is a UL555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-1WT is a UL 555C classified damper for installation in wood truss construction with ratings up to one hour. These assemblies are given proprietary design numbers listed in the UL Fire Resistance Directory.
The CRD-2 is a UL555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-1LP is an ETL Listed damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less. This model is intended to be used on applications with limited blade clearance.
The CRD-1WJ is a UL 555C classified damper for installation in wood joist construction. These assemblies are given proprietary design numbers listed in the UL Fire Resistance Directory.
The CRD-501 is a round UL555C classified damper with UL555S leakage class I rating.
The CRD-60 is a curtain-style UL 555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-2 is a round ETL listed damper designed to limit radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-2WT is a UL 555C classified damper for installation in wood truss construction with ratings up to one hour. These assemblies have proprietary design numbers listed in the UL Fire Resistance Directory.
The CRD-60X is a UL 555C classified damper with an attached insulation skirt designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The SMDR-501 is Class I leakage rated round smoke damper. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The FSD-331 is a combination fire smoke damper with airfoil blades. This model is rated for use in walls, floors, or partitions with a fire resistance rating of 3 hours or more and a Class I leakage rating. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
Model FSD-212 is a combination fire smoke damper with 3V blades. It installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watch N
The FSD-311V is a vertical blade combination fire smoke damper with airfoil style blades. This model installs in walls or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4,000 fpm Temperature: Up to 250°F 10-Day Fixed Lead Times on Selec
The FSD-312 is a combination fire smoke damper with airfoil blades. It is rated for airflow and leakage in either direction and installs in walls, floors, or partitions. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watc
The FSD-211 is a combination fire smoke damper with 3V-style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2,000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurat
The FSD-311M is a modulating combination fire smoke damper with airfoil style blades. It is rated for airflow and leakage in either direction and installs in walls, floors, or partitions. Pressure: Up to 4 in. wg Velocity: Up to 2,000 fpm Temperature: Up to 250°F 10-Day Fixed Lead Times on Select C