Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
The SMD-201M is a Class I rated modulating smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperatur
The SMD-201 is a Class I leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: U
The SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature:
The SMD-302M is a Class II leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Tempera
The SMD-302 Class II leakage rated smoke damper has airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301V is a Class I leakage rated smoke damper with vertical airfoil blades for operational closure in emergency smoke control situations. This model installs vertically and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-401M is a Class I leakage rated modulating smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velo
The SMD-301M is a Class I leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 3000 f
The SMD-401EF is a Class I leakage rated smoke damper with extruded aluminum airfoil blades and frame for operational closure in emergency smoke control situations. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velo
The SMD-401 is a Class I leakage rated smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to
The SMD-301 is a Class I leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperatur
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10-Day Fixed Lead Times on
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
The Vari-Green transformer provides a 24-volt power source from the existing line voltage at the fan to the motor and controls. It has two dry auxiliary contacts (one normally open and one normally closed) available to signal a motorized damper or interlock with other devices.
The remote dial or touch remote allows the user to manually adjust a fan’s speed from a remote location. These controls mount to a wall using a 2x4 junction box and are supplied with a wall cover plate. The 24VDC transformer, described above, is included with all orders. The Touch Remote includes a
The two-speed control allows motor RPM (fan speed) to operate between two discreet speeds (A or B). There are two methods for switching between speeds: SPDT switch or relay connected to the dry contact input. Wet voltage (115-230VAC) applied to the digital input terminal The two-speed control inclu
The Indoor Air Quality – Temperature / Humidity control monitors the temperature and/or relative humidity in a space. It will automatically adjust the ventilation rate to or from a space by increasing or decreasing the speed of the fan based on the desired set point.
The Indoor Air Quality – VOC control senses the level of Volatile Organic Compounds (VOCs) in a space and automatically adjusts the ventilation rate to the space by increasing or decreasing the speed of the fan based on the level of VOCs present. Ventilating based on the VOC concentration assures t
The Constant Pressure control is quite versatile and can be used to monitor either the static pressure or velocity pressure in a system. The control will automatically adjust the fan speed to maintain a desired static pressure or velocity pressure (used for constant CFM) in the system. This control
The Vari-Green ® HOA provides the hand/off/auto functionality of a motor starter and allows for easy integration into other building systems. Set fan speed at this control (hand mode), stop the fan (off mode), or have another control toggle the fan on/off (auto mode). Two auto modes are available. T
Model XG-2600 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/2-inch centers and 1/2-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2600MC is an extruded aluminum linear bar grille mitered corner section with 1/8-inch bars on 1/2-inch centers and 1/2-inch flanged frame, available in 90°, 135° or special angles (SA) with 0°, 15°, or 30° blade deflection.