Number of Results: 639
Model EHH-601D is a Miami-Dade Qualified and Florida Product Approved stationary horizontal blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. EHH-601D is AMCA 540 Listed for wind-borne debris impact and is a high-performance AMCA
Model EACA-601D is a Miami-Dade Qualified and Florida Product Approved combination louver-damper that protects air intake and exhaust openings in exterior walls. The design allows the damper blades to be open or closed and is most often supplied with factory mounted and adjusted electric actuators.
Model XG-RHE is a premier extruded aluminum return and exhaust grille, offering superior construction for high performance and durability. The XG-RHE is available in a number of borders to integrate into a wide range of ceiling and sidewall applications.
Model ESD-635DE is a Miami-Dade Qualified and Florida Product Approved stationary horizontal drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in exterior walls. ESD-635DE is AMCA 540 Listed for wind-borne debris impact and is approved for use in Florida’s
Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-CC1 is an aluminum sidewall or ceiling return/exhaust grille with one-inch x one-inch x one-inch cube core designed to provide low pressure drops and low sound levels. Available in 3-week Industry-leading lead times.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model EHV-901D is a stationary dual-module wind driven rain extruded aluminum louver with horizontal front blades and vertical rear blades designed to protect air intake and exhaust openings in exterior walls. EHV-901 is AMCA 540 Listed for wind-borne debris impact and AMCA 550 Listed for High Velo
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
Model XG-MRDD is an aluminum round architectural double deflection grille with individually adjustable deflection blades.
Model XG-MRDDW is an aluminum round architectural double deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MREC is an aluminum round architectural egg crate grille.
Model XG-MRPF is an aluminum round architectural perforated grille.
Model XG-MRSD is an aluminum round architectural single deflection grille with individually adjustable deflection blades.
Model XG-MRSDW is an aluminum round architectural single deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MPK is an aluminum punkah louver that discharges a directable high-velocity jet to condition a specific space or area.The XG-MPK is constructed using a felt gasket that allows smooth movement of the inner core to direct air flow and provide a tight seal to prevent air leakage.
Model XG-JA diffusers are an excellent choice for high-capacity, long throw applications. The modular design of the XG-JA allows selection for a wide range of air volumes.
Model XG-EPRH is a plastic 2 foot x 2 foot lay-in louver face return grille.
Model XG-EPRHF is a plastic 2 foot x 2 foot lay-in louver face filter return grille with 1 inch deep filter rack.
The WDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. Galvanized steel frame Aluminum blade Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperatu
The SSWDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. 304 stainless steel construction Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperature:
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSSMDR-501 is a Class I leakage-rated round smoke damper constructed of 304 stainless steel. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
The HTD-640 heavy duty industrial air control damper qualified for use in tunnel and transit systems. This model has a double flanged frame and features mechanically fastened silicone blade seals and stainless steel jamb seals. Meets the requirements of NFPA-130, 502, and UL 555S Blade type: Alumin
The HTD-636 is a heavy duty industrial air control damper qualified for use in tunnel and transit systems. This model has a double flanged frame and features mechanically fastened silicone blade seals and stainless steel jamb seals. Meets the requirements of NFPA-130, 502, and UL 555S Fire Rating:
The HTD-630 is a heavy duty industrial air control damper qualified for use in tunnel and transit systems. This model has a double flanged frame and features mechanically fastened silicone blade seals and stainless steel jamb seals. Meets the requirements of NFPA-130, 502, and UL 555S Blade type: f
The HSVR-250 is a heavy-duty industrial round shut-off damper with a flanged frame. Pressure up to 13.5 in. wg Velocity up to 4000 fpm Temperature range -40° to 250°F
The HTD-621 is a heavy duty industrial air control damper qualified for use in tunnel and transit systems. This model has a double flanged frame and features mechanically fastened silicone blade seals and stainless steel jamb seals. Blade type: Single thickness flat blade with reinforcement Pressure
The HSV-230 is a heavy-duty industrial rectangular shut-off damper with a flanged frame. Pressure up to 15 in. wg Velocity to 4000 fpm Temperature from -40° to 250°F
The HBTR-551 is an isolation damper for use in isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 40 in. wg Leakage: Bubble-tight per AMCA 500-D Velocity: Up to 6500 fpm Temperature: -40°F to 250°F
Model HBTR-451 is an isolation damper designed for isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 30 in. wg Leakage: Bubble tight per AMCA 500-D Velocity: Up to 6500 fpm Temperature: -40°F to 250°F
Model HBTR-151 is an isolation damper designed for isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 10 in. wg Leakage: Bubble tight per AMCA 500-D Velocity: Up to 3900 fpm Temperature: -40°F to 250°F
The HBR-050 is a light duty round industrial backdraft damper with a flanged frame. It allows air to be drawn into a draft relief application or to prevent backflow in an HVAC or a process application. Pressure: Up to 6 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
Model HBR-150 is a heavy duty round industrial backdraft damper with a flanged frame. It allows air to be drawn into a draft relief application or to prevent backflow in an HVAC or a process application. Pressure: Up to 6 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F
Model EMV-11 horizontal mount, backdraft damper allows vertical airflow up and prevents reverse airflow down. The damper is opened by air pressure differential and closed by gravity. Standard models include adjustable counterbalance weights to assist with opening. Aluminum construction Pressure: Up
The GM-30 series backdraft dampers allow horizontal airflow and prevent reverse airflow. Dampers in this series include the GM-30 (no flange), GM-31 with a flange on discharge and GM-32 with a flange on intake. Air pressure differential with assistance from adjustable counterbalance weights to mini
The BR-40 series is a pivoted backdraft damper for low-velocity systems. Horizontal mount with a vertical airflow down. Dampers in this series include the BR-40 (no flange) along with BR-41 (flange on discharge) and BR-42 (flange on intake). Back Pressure: 2 in. wg Start-to-Open Pressure: 0.05 in.
The BR-10 series is a pivoted backdraft damper for low-velocity systems. These models mount horizontally to allow vertical airflow up and prevent reverse airflow. Dampers in this series include the BR-10 (no flange) along with BR-11 (flange on discharge) and BR-12 (flange on intake). Back Pressure: