Number of Results: 91
Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
The VCDRM-53 is an insert type multi-blade round control damper providing airflow control in round HVAC ductwork. This damper has applications in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: 3½ cfm per sq. foot @ 1 in. wg Velocity: Up to 2500 fpm Temperature: Up to
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
The VCDR-53 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Leakage: 4 cfm per sq. foot @ 1 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F Blade seal
The VCDR-50 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 10 in. wg Velocity: Up to 4000 fpm Tempe
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Tem
The VCD-43 control damper is low leakage with extruded aluminum airfoil blades and frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8
The VCD-23 is a general purpose control damper with 3V blades. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Velocity: Up to 3
The VCD-33 is a low leakage control damper with fabricated airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in. wg Velocit
The VCD-42 is a low leakage control damper with extruded aluminum airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 6 in. wg Leakage: 3 cfm per sq. foot @ 1in. wg, 6 cfm per s
Model VCD-40 is a low leakage control damper that has blades completely contained within the 4 in. frame. This allows the direct mount to a louver, filter frame, or similar application with no blade interference. Pressure: Up to 6 in. wg Leakage: Class 1A @ 1 in. wg Velocity: Up to 6000 fpm Tempera
The VCD-34 is a low leakage control damper that has insulated fabricated airfoil blades. The damper works well in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in
The VCD-20 is a general purpose control damper with 3V blades. This damper can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Velocity: Up to 3000 fpm Temperature: -40°F to 250°F
The VCD-23V control damper has vertical 3V blades with blade and jam seal. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Veloc
The VCD-43V control damper has low leakage with extruded aluminum airfoil blades and an aluminum frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg,
The VCD-34V is a low leakage control damper with insulated vertical fabricated airfoil blades. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @
The VCD-33V is a low leakage control damper with vertical fabricated airfoil blades. The model can be used as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up 4-8 in. wg Velocity: Up
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10-Day Fixed Lead Times on
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Model XG-2300CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/4-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2000CO is an extruded aluminum core only linear bar grille with 7/32-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2500CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/2-inch centers, available with 0°, 15°, or 30° blade deflection.