Number of Results: 52
A straight-sided roof curb for use on flat roofs in high wind and seismic applications. 8 to 42 in. heights 2 or 5 in. flashing flange
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
Model EDK-430 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates a drainable head, 30-degree K-style blades and a sloped sill. 4-inch depth 55% free area (4 ft. x 4 ft.) 1,002 fpm free area velocity at the
Model EDJ-401 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates a drainable head, J-style blades and a sloped sill. 4-inch depth 52% free area (4 ft. x 4 ft.) 963 fpm free area velocity at the beginning p
Model EDJ-601 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates a drainable head, J-style blades and a sloped sill. 6-inch depth 54% free area (4 ft. x 4 ft.) 998 fpm free area velocity at the beginning p
Model ESJ-401 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates J-style blades, sloped sill and a hidden vertical mullions when configured as multiple sections wide. 4-inch depth 53% free area (4 ft. x 4
Model ESJ-202 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates J-style blade sloped sill and hidden vertical mullions when configured as multiple sections wide. 2-inch depth 38% free area (4 ft. x 4 ft.)
Model ESJ-602 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates J-style blade sloped sill and hidden vertical mullions when configured as multiple sections wide. 6-inch depth 55% free area (4 ft. x 4 ft.)
Model EDD-601 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal dual-drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravit
Model EDD-401 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal dual-drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravit
Model EHM-601 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal dual-drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravit
Model ESK-402 is an extruded aluminum stationary non-drainable louver that protects air intake and exhaust openings in exterior walls. The design incorporates K-style blade sloped sill and hidden vertical mullions when configured as multiple sections wide. 4-inch depth 53% free area (4 ft. 4 ft.) 6
Model SED-501 is an extruded aluminum stationary drainable sightproof louvers with drainable chevron-style blades that protect the intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable sightproof blades collect and channel water to the vertical downsp
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 10 in. wg Velocity: Up to 4000 fpm Tempe
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Tem
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10-Day Fixed Lead Times on
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Model ESD-635 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity take
Model ESD-435 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity tak
Model ESD-603 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity tak
Model ESD-403 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity tak
Model ESD-202 is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity tak
A straight-sided, vented roof curb for use on flat roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange
Model ESD-635HP is an extruded aluminum stationary drainable louver that protects air intake and exhaust openings in exterior walls. The drainable head and stationary horizontal drainable blades collect and further channel water to the vertical downspouts located in the louver jambs where gravity ta
A straight-sided roof curb for use on ridged or double-pitched roofs in high wind and seismic applications. 8 to 24 in. heights 2 or 5 in. flashing flange
A straight-sided roof curb for use on pitched roofs in high wind or seismic applications. 8 to 24 in. heights 2 or 5 in. flashing flange
A canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The cant aides in transition of roofing material. 8 to 20 in. heights 1 1/8 in. flashing flange
A straight-sided roof curb for use on ridged or double-pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A raised canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The raised cant is available up to 6 in. tall for deck insulation. 8 to 20 in. heights 1 1/8 in. flashing flange
A straight-sided roof curb for use on pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A straight-sided roof curb for use on flat roofs. Includes a wood nailer for the attachment roofing material. 12 to 42 in. heights 2 in. flashing flange