Number of Results: 92
The FSD-311M is a modulating combination fire smoke damper with airfoil style blades. It is rated for airflow and leakage in either direction and installs in walls, floors, or partitions. Pressure: Up to 4 in. wg Velocity: Up to 4,000 fpm Temperature: Up to 350°F
The FSD-311 is a combination fire smoke damper with airfoil blades. This model installs in walls, floors, or partitions and has a rating for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The FSD-213 is a combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and has a rating for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The FSD-211M is a modulating combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 250°F
The FSDR-511 is a round combination fire smoke damper with round style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Tem
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 10 in. wg Velocity: Up to 4000 fpm Tempe
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
The SMD-201M is a Class I rated modulating smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperatur
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
The SMD-201 is a Class I leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: U
The SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature:
The SMD-302M is a Class II leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Tempera
The SMD-302 Class II leakage rated smoke damper has airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301V is a Class I leakage rated smoke damper with vertical airfoil blades for operational closure in emergency smoke control situations. This model installs vertically and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301M is a Class I leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 f
The SMD-401M is a Class I leakage rated modulating smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velo
The SMD-401EF is a Class I leakage rated smoke damper with extruded aluminum airfoil blades and frame for operational closure in emergency smoke control situations. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velo
The SMD-401 is a Class I leakage rated smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to
The SMD-301 is a Class I leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperatur
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Model EAD-635 is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-moun
Model EAD-401 is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-moun
Model EAD-632W is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-mou
A straight-sided, vented roof curb for use on flat roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange
A straight-sided roof curb for use on ridged or double-pitched roofs in high wind and seismic applications. 8 to 24 in. heights 2 or 5 in. flashing flange
A straight-sided roof curb for use on flat roofs in high wind and seismic applications. 8 to 42 in. heights 2 or 5 in. flashing flange
A canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The cant aides in transition of roofing material. 8 to 20 in. heights 1 1/8 in. flashing flange
A raised canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The raised cant is available up to 6 in. tall for deck insulation. 8 to 20 in. heights 1 1/8 in. flashing flange
A straight-sided roof curb for use on ridged or double-pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A straight-sided roof curb for use on pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A straight-sided roof curb for use on flat roofs. Includes a wood nailer for the attachment roofing material. 12 to 42 in. heights 2 in. flashing flange
A straight-sided, vented roof curb for use on pitched roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange
A straight-sided, vented roof curb for use on ridged or double-pitched roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange