The SSSMDR-501 is a Class I leakage-rated round smoke damper constructed of 304 stainless steel. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
The SSSMD-201 is a Class I leakage rated smoke damper with 304 stainless steel construction and 3V blades. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The SMDR-501 is Class I leakage rated round smoke damper. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 10 in. wg Velocity: Up to 4000 fpm Tempe
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Tem
The SMD-201M is a Class I rated modulating smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperatur
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
The SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature:
The SMD-201 is a Class I leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: U
The SMD-302M is a Class II leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Tempera
The SMD-302 Class II leakage rated smoke damper has airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301V is a Class I leakage rated smoke damper with vertical airfoil blades for operational closure in emergency smoke control situations. This model installs vertically and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301M is a Class I leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 f
The SMD-401M is a Class I leakage rated modulating smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velo
The SMD-401EF is a Class I leakage rated smoke damper with extruded aluminum airfoil blades and frame for operational closure in emergency smoke control situations. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velo
The SMD-401 is a Class I leakage rated smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to
The SMD-301 is a Class I leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperatur
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10-Day Fixed Lead Times on
A straight-sided, vented roof curb for use on flat roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange
A straight-sided roof curb for use on ridged or double-pitched roofs in high wind and seismic applications. 8 to 24 in. heights 2 or 5 in. flashing flange
A straight-sided roof curb for use on pitched roofs in high wind or seismic applications. 8 to 24 in. heights 2 or 5 in. flashing flange
A straight-sided roof curb for use on flat roofs in high wind and seismic applications. 8 to 42 in. heights 2 or 5 in. flashing flange
A canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The cant aides in transition of roofing material. 8 to 20 in. heights 1 1/8 in. flashing flange
A raised canted roof curb for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The raised cant is available up to 6 in. tall for deck insulation. 8 to 20 in. heights 1 1/8 in. flashing flange
A straight-sided roof curb for use on ridged or double-pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A straight-sided roof curb for use on pitched roofs. Includes a wood nailer for the attachment of roofing material. 12 to 24 in. heights 2 in. flashing flange
A straight-sided roof curb for use on flat roofs. Includes a wood nailer for the attachment roofing material. 12 to 42 in. heights 2 in. flashing flange
A straight-sided, vented roof curb for use on pitched roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange
A straight-sided, vented roof curb for use on ridged or double-pitched roofs in kitchen applications. 20, 24, 26, or 30 in. height, varies by size 2 or 5 in. flashing flange