The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
Model EACA-601 is an extruded aluminum combination louver-damper with drainable style blades, airfoil style damper blades and concealed damper linkage within the louver jambs. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other
Model ECD-401 is an extruded aluminum combination louver-damper with drainable style blades and rear blade linkage, which allows ECD-401 to be manufactured in larger individual panel sizes than similar concealed linkage products. When in the open position this louver functions as a conventional lou
Model GCE-402 is an extruded aluminum combination louver-damper with J-style blades and gravity operated exhaust damper. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. It is recommended
Model ECD-601 is an extruded aluminum combination louver-damper with drainable style blades and rear blade linkage, which allows ECD-601 to be manufactured in larger individual panel sizes than similar concealed linkage products. When in the open position this louver functions as a conventional lou
Model EACC-401 is an extruded aluminum combination louver-damper with drainable style blades and concealed damper linkage within the louver jambs. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed p
Model EAH-690 is an adjustable extruded aluminum louver with drainable head and J-style blades, which open to a full 90º position to allow for maximum free area. This louver is ideally suited for high volume exhaust applications. The louver provides a tight shut off from air and other elements when
Model EACC-601 is an extruded aluminum combination louver-damper with drainable style blades and concealed damper linkage within the louver jambs. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed p
Model EAC-601 is an extruded aluminum combination louver-damper with drainable style blades and concealed damper linkage within the louver jambs. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed po
Model EAC-401 is an extruded aluminum combination louver-damper with drainable style blades and concealed damper linkage within the louver jambs. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed po
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 10 in. wg Velocity: Up to 4000 fpm Tempe
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Tem
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperat
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F 10-Day Fixed Lead Times on
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Model EAD-635 is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-moun
Model EAD-401 is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-moun
Model EAD-632W is an adjustable extruded aluminum louver with drainable style blades. When in the open position this louver functions as a conventional louver while providing tight shut off from air and other elements when in the closed position. This product is most often provided with factory-mou
A canted equipment support for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The cant aides in transition of roofing material. 8, 12 or 14 in. heights 4, 6, or 8 in. widths
A raised canted equipement support for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The raised cant is available up to 6 in. tall for deck insulation. 8, 12 or 14 in. heights 4, 6, or 8 in. widths
A straight-sided equipment support for use on flat or pitched roofs. Includes a wood nailer for the attachment of roofing material. 8 to 18 in. heights 4, 6, or 8 in. widths
Model XG-L is an aluminum ceiling supply grille with long adjustable curved blades and one-way air pattern.
Model XG-LTC3M is an aluminum ceiling supply grille with three-way corner air pattern, curved blades that are individually adjustable and multi-shutter damper.
Model XG-LTV is an aluminum double deflection ceiling supply grille with two-way air pattern, curved front blades and rear vertical blades that are individually adjustable.
Model XG-H4002 is an aluminum sidewall supply grille with horizontal single deflection blades that are individually adjustable. Available in 3-week Industry-leading lead times.
Model XG-V4002 is an aluminum sidewall supply grille with vertical single deflection blades that are individually adjustable. Available in 3-week Industry-leading lead times.
Model XG-H4002S is a steel sidewall supply grille with horizontal single deflection blades that are individually adjustable. Available in 3-week Industry-leading lead times.
Model XG-V4002-AF is an extruded aluminum sidewall supply grille with vertical airfoil single deflection blades that are individually adjustable.
Model XG-H4002-AF is an extruded aluminum sidewall supply grille with horizontal airfoil single deflection blades that are individually adjustable.
Model XG-V4002S is a steel sidewall supply grille with vertical single deflection blades that are individually adjustable. Available in 3-week Industry-leading lead times.
Model XG-H4002S-AF is a sidewall supply grille with a steel border and horizontal extruded aluminum airfoil single deflection blades that are individually adjustable.
Model XG-V4002S-AF is a sidewall supply grille with a steel border and vertical extruded aluminum airfoil single deflection blades that are individually adjustable.