Number of Results: 196
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
The CRD-60 is a curtain-style UL 555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
A canted equipment support for use on flat roofs. Includes a wood nailer for the attachment of roofing material. The cant aides in transition of roofing material. 8, 12 or 14 in. heights 4, 6, or 8 in. widths
The WDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. Galvanized steel frame Aluminum blade Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperatu
The SSWDR-53 round backdraft damper is designed to mount horizontally for airflow down or up; or vertical for horizontal airflow. This damper is opened by air pressure differential and closed by springs. 304 stainless steel construction Pressure: Up to 3 in. wg Velocity: Up to 2000 fpm Temperature:
The SSSMDR-501 is a Class I leakage-rated round smoke damper constructed of 304 stainless steel. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 212°F
The HSVR-250 is a heavy-duty industrial round shut-off damper with a flanged frame. Pressure up to 13.5 in. wg Velocity up to 4000 fpm Temperature range -40° to 250°F
The HSV-230 is a heavy-duty industrial rectangular shut-off damper with a flanged frame. Pressure up to 15 in. wg Velocity to 4000 fpm Temperature from -40° to 250°F
The HBTR-551 is an isolation damper for use in isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 40 in. wg Leakage: Bubble-tight per AMCA 500-D Velocity: Up to 6500 fpm Temperature: -40°F to 250°F
Model HBTR-451 is an isolation damper designed for isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 30 in. wg Leakage: Bubble tight per AMCA 500-D Velocity: Up to 6500 fpm Temperature: -40°F to 250°F
The HBR-050 is a light duty round industrial backdraft damper with a flanged frame. It allows air to be drawn into a draft relief application or to prevent backflow in an HVAC or a process application. Pressure: Up to 6 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
Model HBR-150 is a heavy duty round industrial backdraft damper with a flanged frame. It allows air to be drawn into a draft relief application or to prevent backflow in an HVAC or a process application. Pressure: Up to 6 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F
Model HBTR-151 is an isolation damper designed for isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 10 in. wg Leakage: Bubble tight per AMCA 500-D Velocity: Up to 3900 fpm Temperature: -40°F to 250°F
The GM-30 series backdraft dampers allow horizontal airflow and prevent reverse airflow. Dampers in this series include the GM-30 (no flange), GM-31 with a flange on discharge and GM-32 with a flange on intake. Air pressure differential with assistance from adjustable counterbalance weights to mini
Model EMV-11 horizontal mount, backdraft damper allows vertical airflow up and prevents reverse airflow down. The damper is opened by air pressure differential and closed by gravity. Standard models include adjustable counterbalance weights to assist with opening. Aluminum construction Pressure: Up
The BR-40 series is a pivoted backdraft damper for low-velocity systems. Horizontal mount with a vertical airflow down. Dampers in this series include the BR-40 (no flange) along with BR-41 (flange on discharge) and BR-42 (flange on intake). Back Pressure: 2 in. wg Start-to-Open Pressure: 0.05 in.
The BR-30 series is a pivoted backdraft damper for low-velocity systems. These models are vertical mount dampers, designed to allow horizontal airflow and prevent reverse airflow. Dampers in this series include the BR-30 (no flange) along with BR-31 (flange on discharge) and BR-32 (flange on intake
The BR-10 series is a pivoted backdraft damper for low-velocity systems. These models mount horizontally to allow vertical airflow up and prevent reverse airflow. Dampers in this series include the BR-10 (no flange) along with BR-11 (flange on discharge) and BR-12 (flange on intake). Back Pressure:
The SEBR-40 series feature 316 stainless steel construction. It is a pivoted backdraft damper for low-velocity systems. These models are horizontally mounted dampers to allow vertical airflow down and prevent reverse airflow. Dampers in this series include the SEBR-40 (no flange) along with SEBR-41
The SEBR-10 series feature 316 stainless steel construction. It is a pivoted backdraft damper for low-velocity systems. Models mount horizontally, allow vertical airflow up and prevent reverse airflow. Dampers in this series include the SEBR-10 (no flange) along with SEBR-11 (flange on discharge) a
The SEBR-30 series feature 316 stainless steel construction. It is a pivoted backdraft damper for low-velocity systems. Dampers in this series include the SEBR-30 (no flange) along with SEBR-31 (flange on discharge) and SEBR-32 (flange on intake). These models are vertical mounted, allow horizontal
Model AMD-42V combines the functionality of an accurate airflow measuring station and a low-leakage vertical blade control damper into one compact assembly that measures and regulates airflow volumes to a target set point. This model comes standard with a modulating actuator and properly sized pres
The AMD-42 combines the functionality of an accurate airflow measuring station and a low-leakage control damper into one compact assembly that measures and regulates airflow volumes to a target set point. This model comes standard with a modulating actuator and properly sized pressure transducer th
The AMD-33 combines the functionality of an accurate airflow measuring station and a low-leakage control damper into one compact assembly that measures and regulates airflow volumes to a target set point. This model comes standard with a modulating actuator and properly sized pressure transducer th
The AMD-23 combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that measures and regulates airflow volumes to a target set point. This model comes standard with a modulating actuator and properly sized pressure transducer th
The CFSD-211 is a combination fire smoke damper for corridor ceiling applications and has UL 555 1 hour fire rating and UL 555S leakage class I. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
The EM-10 series are horizontally mounted backdraft dampers designed to allow vertical airflow up and prevent reverse airflow down. Model EM-10 has no flange, model EM-11 has a flange on the discharge side, and model EM-12 has a flange on the intake side. All dampers in this series open by air pres
The EM-40 series are horizontally mounted backdraft dampers designed to allow vertical airflow down and prevent reverse airflow up. Model EM-40 has no flange, model EM-41 has a flange on the discharge side, and model EM-42 has a flange on the intake side. All dampers in this series open by air pres
The EM-30 series are vertically mounted backdraft dampers designed to allow horizontal airflow. Model EM-30 has no flange, model EM-31 has a flange on the discharge side, and model EM-32 has a flange on the intake side. All dampers in this series open by air pressure differential and close by gravi
The intended use for FBV-23 face and bypass control dampers are in low to medium pressure and velocity systems. The control damper features 3V blades and is IECC (International Energy Conservation Code) compliant. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1 in. wg; Class 1 @ up to 5 in. wg Veloc
Model GFSD-211 is an out of wall combination fire smoke damper with 3V blades. Its design allows for easy access through the grille to the damper, closure device, and the actuator. This model can install vertically or horizontally and is rated for airflow and leakage in either direction. UL 555 1½
Model HB-240 industrial backdraft damper has standard extruded aluminum airfoil blades. The damper comes standard with Spark B and C construction with Spark A construction optional. Pressure: Up to 13½ in. wg Velocity: Up to 5150 fpm Temperature: -40°F to 250°F Spark B & C construction, optional Sp
The HB-230 is a heavy duty industrial backdraft damper. It has a double flanged channel frame and fabricated airfoil blades. Pressure: Up to 13½ in. wg Velocity: Up to 5150 fpm Temperature: -20°F to 250°F
Model HB-120 is a heavy duty industrial backdraft damper with a double-flanged channel frame and single thickness blades. Pressure: Up to 8.5 in. wg Velocity: Up to 5150 fpm Temperature: -20°F to 180°F with seals; -20°F to 250°F without seals
The HB-110 is a heavy duty industrial backdraft damper with a double-flanged galvanized steel channel frame and extruded aluminum blades. Backdraft dampers are designed to allow airflow in one direction and prevent reverse airflow. These can be used as exhaust or intake dampers. Pressure: Up to 5 i
The HB-330 heavy duty industrial backdraft damper features a double flanged galvanized steel frame and double thickness fabricated airfoil blades. External heavy duty linkage, blade counterbalance and ball bearings all are standard. Pressure: Up to 20 in. wg Velocity: Up to 6400 fpm Temperature: -4
The HBS-331 blast suppression damper closes in the opposite direction as normal airflow. These dampers protect against rapid pressure changes due to an explosion (as high as 5.77 psi). Pressures: 1.5 - 5.77 psi to the maximum size Velocity: Up to 4000 fpm Temperature: -40°F to 250°F
The HBS-330 blast suppression damper closes in the same direction as the normal airflow. These dampers protect against rapid pressure changes due to an explosion (as high as 5.77 psi). Pressures: 1.5 - 5.77 psi to the maximum size Velocity: Up to 4000 fpm Temperature: -40°F to 250°F
The HBT-221 is an isolation damper designed for isolation and decontamination applications. The damper has bubble-tight leakage performance per AMCA 500-D. Pressure: Up to 10 in. wg Leakage: Bubble tight per AMCA 500-D Velocity: Up to 3900 fpm Temperature: -40°F to 250°F