| Sustainable Sites [+] | 14 Points |
| Prereq 1 |
Construction Activity Pollution Prevention |
Required |
| Credit 1 |
Site Selection |
1 |
| Credit 2 |
Development Density & Community Connectivity |
1 |
| Credit 3 |
Brownfield Redevelopment |
1 |
| Credit 4.1 |
Alternative Transportation, Public Transportation Access |
1 |
| Credit 4.2 |
Alternative Transportation, Bicycle Storage & Changing Rooms |
1 |
| Credit 4.3 |
Alternative Transportation, Low-Emitting & Fuel-Efficient Vehicles |
1 |
| Credit 4.4 |
Alternative Transportation, Parking Capacity |
1 |
| Credit 5.1 |
Site Development, Protect or Restore Habitat |
1 |
| Credit 5.2 |
Site Development, Maximize Open Space |
1 |
| Credit 6.1 |
Stormwater Design, Quantity Control |
1 |
| Credit 6.2 |
Stormwater Design, Quality Control |
1 |
| Credit 7.1 |
Heat Island Effect, Non-Roof |
1 |
| Credit 7.2 |
Heat Island Effect, Roof |
1 |
| Credit 8 |
Light Pollution Reduction |
1 |
| Water Efficiency [+] | 10 Points |
| Prereq 1 |
Water Use Reduction - 20% Reduction |
Required |
| Credit 1 |
Water Efficient Landscaping |
2 to 4 |
| |
Water Efficient Landscaping, Reduce by 50% |
2 |
| |
Water Efficient Landscaping, No Potable Use or No Irrigation |
4 |
| Credit 2 |
Innovative Wastewater Technologies |
1 |
| Credit 3 |
Water Use Reduction |
2 to 4 |
| |
Water Use Reduction, 30% Reduction |
2 |
| |
Water Use Reduction, 35% Reduction |
3 |
| |
Water Use Reduction, 40% Reduction |
4 |
| Energy & Atmosphere [+] | 35 Points |
| Prereq 1 |
Fundamental Commissioning of the Building Energy Systems |
Required |
| Prereq 2 |
Minimum Energy Performance |
Required |
| Prereq 3 |
Fundamental Refrigerant Management |
Required |
| *Note for EAc1: All LEED for New Construction projects registered after June 26th, 2007 are required to achieve at least two (2) points under EAc1. |
| Credit 1 |
Optimize Energy Performance |
1 to 19 |
| |
12% New Buildings or 8% Existing Building Renovations |
1 |
| |
14% New Buildings or 10% Existing Building Renovations |
2 |
| |
16% New Buildings or 12% Existing Building Renovations |
3 |
| |
18% New Buildings or 14% Existing Building Renovations |
4 |
| |
20% New Buildings or 16% Existing Building Renovations |
5 |
| |
22% New Buildings or 18% Existing Building Renovations |
6 |
| |
24% New Buildings or 20% Existing Building Renovations |
7 |
| |
26% New Buildings or 22% Existing Building Renovations |
8 |
| |
28% New Buildings or 24% Existing Building Renovations |
9 |
| |
30% New Buildings or 26% Existing Building Renovations |
10 |
| |
32% New Buildings or 28% Existing Building Renovations |
11 |
| |
34% New Buildings or 30% Existing Building Renovations |
12 |
| |
36% New Buildings or 32% Existing Building Renovations |
13 |
| |
38% New Buildings or 34% Existing Building Renovations |
14 |
| |
40% New Buildings or 36% Existing Building Renovations |
15 |
| |
42% New Buildings or 38% Existing Building Renovations |
16 |
| |
44% New Buildings or 40% Existing Building Renovations |
17 |
| |
46% New Buildings or 42% Existing Building Renovations |
18 |
| |
48%+ New Buildings or 44%+ Existing Building Renovations |
19 |
| Credit 2 |
On-Site Renewable Energy |
1 to 7 |
| |
1% Renewable Energy |
1 |
| |
3% Renewable Energy |
2 |
| |
5% Renewable Energy |
3 |
| |
7% Renewable Energy |
4 |
| |
9% Renewable Energy |
5 |
| |
11% Renewable Energy |
6 |
| |
13% Renewable Energy |
7 |
| Credit 3 |
Enhanced Commissioning |
1 |
| Credit 4 |
Enhanced Refrigerant Management |
1 |
| Credit 5 |
Measurement & Verification |
1 |
| Credit 6 |
Green Power |
1 |
| Materials & Resources [+] | 14 Points |
| Prereq 1 |
Storage & Collection of Recyclables |
Required |
| Credit 1.1 |
Building Reuse, Maintain Existing Walls, Floors & Roof |
1 to 3 |
| |
Reuse 55% |
1 |
| |
Reuse 75% |
2 |
| |
Reuse 95% |
3 |
| Credit 1.2 |
Building Reuse, Maintain 50% of Interior Non-Structural Elements |
1 |
| Credit 2 |
Construction Waste Management |
1 to 2 |
| |
50% Recycled or Salvaged |
1 |
| |
75% Recycled or Salvaged |
2 |
| Credit 3 |
Materials Reuse |
1 to 2 |
| |
Reuse 5% |
2 |
| |
Reuse 10% |
2 |
| Credit 4 |
Recycled Content |
1 to 2 |
| Credit 4.1 |
10% of Content |
1 |
| Credit 4.2 |
20% of Content |
2 |
| Credit 5 |
Regional Materials |
1 to 2 |
| Credit 5 |
10% of Materials |
1 |
| Credit 5 |
20% of Materials |
1 |
| Credit 6 |
Rapidly Renewable Materials |
1 |
| Credit 7 |
Certified Wood |
1 |
| Indoor Environmental Quality [+] | 15 Points |
| Prereq 1 |
Minimum Indoor Air Quality Performance |
Required |
| Prereq 2 |
Environmental Tobacco Smoke (ETS) Control |
Required |
| Credit 1 |
Outdoor Air Delivery Monitoring |
1 |
| Credit 2 |
Increased Ventilation |
1 |
| Credit 3.1 |
Construction IAQ Management Plan During Construction |
1 |
| Credit 3.2 |
Construction IAQ Management Plan Before Occupancy |
1 |
| Credit 4.1 |
Low-Emitting Materials Adhesives & Sealants |
1 |
| Credit 4.2 |
Low-Emitting Materials Paints & Coatings |
1 |
| Credit 4.3 |
Low-Emitting Materials Flooring Systems |
1 |
| Credit 4.4 |
Low-Emitting Materials Composite Wood & Agrifiber Products |
1 |
| Credit 5 |
Indoor Chemical & Pollutant Source Control |
1 |
| Credit 6.1 |
Controllability of Systems Lighting |
1 |
| Credit 6.2 |
Controllability of Systems, Thermal Comfort |
1 |
| Credit 7.1 |
Thermal Comfort, Design |
1 |
| Credit 7.2 |
Thermal Comfort Verification |
1 |
| Credit 8.1 |
Daylight & Views Daylight 75% of Spaces |
1 |
| Credit 8.2 |
Daylight & Views Daylight 90% of Spaces |
1 |
| Innovation & Design Process [+] | 6 Points |
| Credit 2 |
LEED® Accredited Professional |
1 |
| Project Totals (pre-certification estimates) | 100 Points |
| Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80 to 100 points |